107
e-31
EEPROM
fault
Data writing
and read errors
occur.
The inverter
has power
failure during
parameter reset.
Power on the inverter
to eliminate the fault. If
the fault can not be
eliminated, contact
QIROD or its
distributor for
maintenance or repair
of the inverter.
e-32
Control
board fault
Control board
cannot work
Connect
manufacturer to
maintain
e-33
Communic
ation fault
Network
communication
error.
Check network
control devices and
cables.
Check the setting of
communication
overtime parameter
f803.
Check remote
keyboard panel cable.
e-34
Current
sensor
fault
The current
sensor is in
abnormal status.
Replace the inverter.
e-35
Network
fault
Network error
Check network
control devices and
cables.
e-36
Inverter
type error
Inverter
hardware fault
f120=7
If error is still,
connect manufacturer
to maintain
Code of
fault
Type of fault
Possible cause