EasyManua.ls Logo

Qirod QD100 Series - Page 151

Default Icon
163 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
149
[-f5-]
NO.
Parameter
Name
Setting Range default
WRT
User
setting
f500
Auto-restart
control selection
0: Disabled
1: At auto-restart after
momentary stop
2: When turning
standby (input
terminal function =1)
on or off
3: At auto-restart or
when turning standby
(input terminal
function =1) on or off
4: At start-up
5-7: Factory reserved
8: Fistly, DC brake,
then restart
0
f501
auto-stop time
limit for lower-
limit frequency
operation
0.0: disable
0.1-600.0 s
0.1
f502
Bumpless
operation
selection
0: disabled.
1: enabled.
1
f503
Starting
frequency setting
0.5~10.0 Hz 0.5
f504
Operation
starting
frequency
0.0 Hz ~f007 0.0
f505
Operation
starting
frequency
hysteresis
0.0 Hz ~f007 0.0
f506
DC braking
starting
frequency
0.0 Hz ~f007 0.0

Table of Contents