RADWIN5000HPMPUserManual Release3.5.70 8‐22
Security
2.Choosethecommunitiestobechangedbyclickingthecheckbox.
3.TypethenewCommunitystringandre‐typetoconfirm.Acommunitystringmust
containatleastfiveandnomorethan32charactersexcludingSPACE,TAB,andany
of“>#@|*?;."
4.ClickOKtosave.
EditingSNMPv3Passwords
Tocommencetheprocess,youmustenterthecurrentRead‐WriteCommunitypasswordas
showninthefirstfieldofFigure 8‐9below.ChangetheRead‐WriteandRead‐Onlypasswords
asindicated.Apasswordmustbebetween8and31characterslong.Thesamecharacter
restrictionsfortheSNMPv1communitystringsalsoapplyhere.
Figure8‐9:ChangingtheCommunityStrings/Passwords
ForgottenSNMPv1CommunityString
Iftheread‐writeCommunitystringisunknown,analternativeCommunity keycanbeused.
ThealternativeCommunitykeyisuniqueperODUandcanbeusedonlytochangethe
Communitystrings.ThealternativeCommunitykeyissuppliedwiththeproduct,andshould
bekeptinasafeplace.
Ifboththeread‐writeCommunityandthealternativeCommunitykeyareunavailable,then
analternativeCommunitykeycanbeobtainedfromRADWINCustomerServiceusingthe
ODUserialnumberorMACaddress.Theserialnumberislocatedontheproductlabel.The
serialnumberandtheMACaddressaredisplayedintheSiteConfigurationinventorytab.
WhenyouhavethealternativeCommunitykey ,clicktheForgotCommunitybuttonandenter
theAlternativeCommunitykey(Figure 8‐10).Thenchangetheread‐writeCommunitystring.