Dewatering System Trouble shooting:
1. Compression Loss. Check de-watering valves as they are not properly closing. Replace not closing valve.
2. Dewatering system not working. Check rods to insure working properly. Tighten as required. The
dewatering system is mechanical and should not be prone to failure.
3. Fuel is not discharging after submersion. Check brass valves that get initiated when the dewatering slide is
moved toward back of engine. Blow out line; if still does not work replace all three valves (one assembly)

Table of Contents