Maintenance
GB
4) Inspection of Cooling Water Passage
1
MX50
B
1
1.
Check that cooling water intake is not clogged. Clean if
necessary.
2. Set lower unit in the water and start engine.
3. Check that cooling water check port 1 ejects water.
5) Flushing with Water
WARNING
3
A
Be careful not to touch rotating propeller.
Be sure to remove propeller before running
engine on the land.
WARNING
2
2 Tape 3 Flushing Attachment
MWX50
A
OIL
3
WASH
1
B
2
Exhaust gas contains carbon monoxide
which can cause intoxication if inhaled. Do
not operated engine in a closed space such
as interior of boat house.
Flushing using flushing attachment (P/N3B7-60007-0).
1. Remove the following parts.
Propeller and thrust holder
1 Water plug.
2. Attach the following parts.
2 Tape:Two locations (on the water strainer)
3 Flushing attachment
Put water hose from water outlet to 3 and run water.
Set shift lever to neutral (N) and start engine.
Check that cooling water check port discharges water,
and run engine for 3 to 5 minutes at idle speed.
Stop engine and stop water supply, remove 3, attach
and tighten 1, and then, reinstall propeller parts
2 Tape 3 Flushing Attachment
removed.
3-10
2st X50D2 2011