each successful keypress a “1” momentarily will appear while the key is
engaged.
The speed and temperature will show numeric values which indicate that
incoming data is detected. The values displayed are not the actual readout
data, itself.
424
Auio
‘Ibmperature
Calibrate Mode
Ordinarily the surface water temperature sensor can be calibrated over a
limited range to provide accurate temperature readouts on the echo
sounder display in the Calibration menu. If the correct temperature adjust-
ment range cannot be obtained, the echo sounder may be automatically
re-calibrated to the proper factorytemperature standard by
performing
the
following steps:
1.
2.
‘Ihm
the power to the echo sounder OFF.
Disconnect the Speed/Temperature plug.
TEMPAOJUST
SETFEG.
1OKR
Make up a test plug consisting of a 8 pm
Fujitsu connector and a
1OK
ohm,
l/4
w,
5
%
resistor attached to pins 6
&
7
of the plug.
~PRESSAlARt.4 KEY
ADJUST OK
3. Plug in the temperature test plug . Press and
hold
them
key while pressing
the/q
key to ON. The Temp Adjust screen appears.
After several seconds the message
”
PRESS ALARM KEY" appears. When
the
m
key is pressed, the calibration status message "ADJUST
OK"
appears if the calibration has been successful. The unit will automatically
reset the internal temperature calibration value to approximately
25’
C
with the
1OK
ohm applied to terminals 6
&
7 of the plug.
425 Service Alignments
This section provides information and instructions concerning
dis-assem-
bly and internal alignments for the
V8010
Color Echosounder.
WARNING
HIGHVOLTAGEISPRESENTWlTHIN
Tars
EQUIPMENT. CONTACT WITH THIS
VOLTAGE
COULD
BE LETHAL.
MAINTENANCE 116