RL78/F13, F14 CHAPTER 16 SERIAL INTERFACE IICA
R01UH0368EJ0210 Rev.2.10 1067
Dec 10, 2015
(1) Master device operation
(a) Start ~ Address ~ Data ~ Data ~ Stop (transmission/reception)
(i) When WTIM0 = 0
1: IICS0 = 1000×110B
2: IICS0 = 1000×000B
3: IICS0 = 1000×000B (Sets the WTIM0 bit to 1)
Note
4: IICS0 = 1000××00B (Sets the SPT0 bit to 1)
Note
5: IICS0 = 00000001B
Note To generate a stop condition, set the WTIM0 bit to 1 and change the timing for generating the INTIICA0
interrupt request signal.
Remark : Always generated
: Generated only when SPIE0 = 1
×: Don’t care
(ii) When WTIM0 = 1
1: IICS0 = 1000×110B
2: IICS0 = 1000×100B
3: IICS0 = 1000××00B (Sets the SPT0 bit to 1)
4: IICS0 = 00000001B
Remark : Always generated
: Generated only when SPIE0 = 1
×: Don’t care
ST AD6 to AD0 R/W ACK D7 to D0 D7 to D0ACK ACK SP
SPT0 = 1
↓
3 4 5 2
1
ST AD6 to AD0 R/W ACK D7 to D0 D7 to D0ACK ACK SP
SPT0 = 1
↓
3 4 2
1