RL78/F13, F14 CHAPTER 12 A/D CONVERTER
R01UH0368EJ0210 Rev.2.10 710
Dec 10, 2015
Cautions 1. If using the hardware trigger wait mode, setting the ADCS bit to 1 is prohibited (but the bit is
automatically switched to 1 when the hardware trigger signal is detected). However, it is possible
to clear the ADCS bit to 0 to specify the A/D conversion standby status.
2. While in the one-shot conversion mode of the hardware trigger no-wait mode, the ADCS flag is not
automatically cleared to 0 when A/D conversion ends. Instead, 1 is retained.
3. Only rewrite the value of the ADCE bit when ADCS = 0 (while in the conversion
stopped/conversion standby status).
4. To complete A/D conversion, specify at least the following time as the hardware trigger interval:
Hardware trigger no wait mode: 2 f
CLK clocks + A/D conversion time
Hardware trigger wait mode: 2 f
CLK clocks + stabilization wait time + A/D conversion time