BIT SWITCHES
B465 5-32 SM
G3 Switch 0A
No. Function Comments
4 Maximum allowable frame
interval during image data
reception.
0: 5 s 1: 13 s
This bit set the maximum interval between EOL
(end-of-line) signals from the other end.
Try using a longer setting if error code 0-21 is
frequent.
5 Not used Do not change the setting.
6
Reconstruction time for the first
line in receive mode
0: 6 s 1: 12 s
When the sending terminal is controlled by a
computer, there may be a delay in receiving page
data after the local machine accepts set-up data and
sends CFR. This is outside the T.30
recommendation. But, if this delay occurs, set this
bit to 1 to give the sending machine more time to
send data.
Refer to error code 0-20.
ITU-T T.30 recommendation: The first line should
come within 5 s of CFR.
7 Not used Do not change the setting.
G3 Switch 0B (Europe only)
No. FUNCTION COMMENTS
0 Protocol requirements: Europe
0: Disabled 1: Enabled
1 Protocol requirements: Spain
0: Disabled 1: Enabled
2
Protocol requirements:
Germany
0: Disabled 1: Enabled
3 Protocol requirements: France
0: Disabled 1: Enabled
4 PTT requirements: Germany
0: Disabled 1: Enabled
Program these bit switches manually to match
local requirements.
5–7 Not used Do not change these settings.
G3 Switch 0C - Not used (do not change any of these settings)
G3 Switch 0D - Not used (do not change any of these settings)
G3 Switch 0E - Not used (do not change any of these settings)