USING SERVICE PROGRAM MODE
B044/B045/B046 5-14 SM
SP5-XXX (Mode)
5
Mode Number/Name Function/[Setting]
All Indicators On001
Sets on all indicators on the operation panel, and causes
the display to blink (empty for five second, all pixels black
for five seconds).
After checking, press ! or Cancel to exit.
Date/Time302*
Sets the date and time.
• For the year value, you can set the last two digits only.
(The first two digits are fixed at "20".)
• You cannot set the seconds value directly. Instead, the
seconds value automatically resets to 0 when you enter
the setting for the minutes value.
• Use cursor keys (or OK) to move from field to field (the
selected field flashes), and enter values with the numeric
keys. Your new settings are saved only if you press OK
while the minutes field is selected.
PM Alarm Mode
1 Interval Sets the base PM interval.
[1 ~ 255 / 45 / 1K copies/step]
This setting is meaningful only if SP5-501-2 is set to “1”.
501*
2 On/Off Enables/disables the PM alarm for the total number of
prints, copies, and faxes.
[0 = Disable / 1 = Enable]
Memory All Clear801
Resets all SP/UP settings and values to their defaults,
with the exception of plug-and-play settings (SP5-907),
total print counters (SP7-003), and the serial number
setting (SP5-811).
(
☛
5.1.6)
[0 = No / 1 = Yes]
• Before clearing the SRAM, be sure to output an SMC
printout of all current SRAM content. (
☛
SP5-992).
• This SP mode should generally not be used.
Free Run802
Starts a free run of both the scanner and the printer.
[0: = No / 1 = Yes]
• For details about free runs:
☛
5.1.7.
• After selecting “1”, press the OK key (or the ' key)
twice to start the free run. Press % to stop the free run.
Input Check803
Displays the signals being received from a selected
sensor or switch.
(
☛
5.1.3
)
Press ! to exit the program.
Output Check804
Turns on a selected electrical component for test
purposes. (
☛
5.1.4)