HOW TO CLEAR THE PM COUNTER
B044/B045/B046 2-2 SM
Every
90k
AN NOTE
DF
Separation roller R C Water or alcohol
Pick-up roller R C Water or alcohol
White plate C Water or alcohol
DF exposure glass C Water
Rollers R0, R1, R2 C Water or alcohol
Every
120k
AN NOTE
PAPER TRAY UNIT
Paper feed roller R
Bottom-plate pad C Dry cloth
Friction pad R
2.2 HOW TO CLEAR THE PM COUNTER
After finishing PM, clear the PM counter as follows.
1. Access SP mode 7-804.
2. Hold down the Original Type key and press the OK key (or ! key) to reset the
counter. If the reset is successful, the display shows “Action completed.” If the
reset fails, the display shows “Error!!!”