NCU PARAMETERS
B465 5-36 SM
Address Function Unit Remarks
401434
International dial tone frequency
upper limit (high byte)
401435
International dial tone frequency
upper limit (low byte)
Hz (BCD)
If both addresses contain
FF(H), tone detection is
disabled.
401436 International dial tone frequency
lower limit (high byte)
401437 International dial tone frequency
lower limit (low byte)
Hz (BCD) If both addresses contain
FF(H), tone detection is
disabled.
401438 International dial tone detection time
401439 International dial tone reset time
(LOW)
40143A International dial tone reset time
(HIGH)
40143B
International dial tone continuous
tone time
40143C
International dial tone permissible
drop time
If 401438 contains FF,
the machine pauses for
the pause time (40143D /
40143E).
Belgium: See Note 2.
40143D International dial wait interval (LOW)
40143E International dial wait interval (HIGH)
20 ms
40143F
Country dial tone upper frequency
limit (HIGH)
401440
Country dial tone upper frequency
limit (LOW)
Hz (BCD)
If both addresses contain
FF(H), tone detection is
disabled.
401441 Country dial tone lower frequency
limit (HIGH)
401442
Country dial tone lower frequency
limit (LOW)
Hz (BCD) If both addresses contain
FF(H), tone detection is
disabled.
401443 Country dial tone detection time
401444 Country dial tone reset time (LOW)
401445 Country dial tone reset time (HIGH)
If 401443 contains FF,
the machine pauses for
the pause time (401448 /
401449).
401446
Country dial tone continuous tone
time
401447 Country dial tone permissible drop
time
401448 Country dial wait interval (LOW)
401449 Country dial wait interval (HIGH)
20 ms
40144A
Time between opening or closing the
DO relay and opening the OHDI
relay
1 ms
See Notes 3, 6 and 7.
Function 07–0
(parameter 11).
40144B Break time for pulse dialing 1 ms See Notes 3 and 7.
Function 07-0 (parameter
12).
40144C Make time for pulse dialing 1 ms See Notes 3 and 7.
Function 07-0 (parameter
13).
40144D Not used Do not change the setting.