NCU PARAMETERS
SM 5-41 B465
Fax Unit
B465
5. The attenuation levels calculated from RAM data are:
High frequency tone: - 0.5 x N
401452/401454
dBm
Low frequency tone: - 0.5 x (N
401452/401454
+ N
401453
) dBm
NOTE: N
401452
, for example, means the value stored in address 401452(H)
6. The actual inter-digit pause (pulse dial mode) is the sum of the periods
specified by RAM addresses 40144A and 40144E.
7. For European models, these parameters should not be changed in the field.
The default values of these parameters have been approved by CTR21 and/or
EG201121. Therefore, a change in any one of these values would constitute a
violation of these requirements.
40144A 40144E 40144A
Inter digit pause
break
B465S555.WMF