Service Call Conditions
D009/D011/D012/D013/D091/D092 3-10 SM Appendix
324 D
Development paddle motor error
The machine detects a lock signal error from the development puddle motor
for 2 seconds after the drum motor has turned on.
Overload on the development puddle motor
Defective development puddle motor
Defective harness
Defective IOB
350 D
ID sensor pattern test error
One of the following readings occurred 10 times in the ID sensor output when
the ID sensor pattern was checked:
1) Vsp > 2.5V
2) Vsg < 2.5V
3) Vsp =0V
4) Vsg = 0V
ID sensor connector defective
Poor ID sensor connector connection
I/O board (IOB) defective
Poor writing of ID sensor pattern on the drum
High voltage supply board defective