EasyManua.ls Logo

Ricoh D009 - Page 394

Ricoh D009
1209 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Service Call Conditions
D009/D011/D012/D013/D091/D092 3-26 SM Appendix
-99 D
Management area error
The management number of the external authentication module exceeds
the maximum limit.
Software error
641 D
BICU communication error
The BICU does not respond to the frame transmitted from the controller.
Defective controller
Detective BICU
650
Communication error of the remote service modem
(Embedded RCG-M)
-001 B
Authentication error
The authentication for the Embedded RCG-M fails at a dial up connection.
Incorrect SP settings
Disconnected telephone line
Disconnected modem board
Check and set the correct user name (SP5816-156) and password
(SP5816-157).
-004 B
Incorrect modem setting
Dial up fails due to the incorrect modem setting.
Same as -001
Check and set the correct AT command (SP5816-160).
-005 -
Communication line error
The supplied voltage is not sufficient due to a defective communication line
or defective connection.
Same as -001