Service Call Conditions
D009/D011/D012/D013/D091/D092 3-26 SM Appendix
-99 D
Management area error
The management number of the external authentication module exceeds
the maximum limit.
Software error
641 D
BICU communication error
The BICU does not respond to the frame transmitted from the controller.
Defective controller
Detective BICU
650
Communication error of the remote service modem
(Embedded RCG-M)
-001 B
Authentication error
The authentication for the Embedded RCG-M fails at a dial up connection.
Incorrect SP settings
Disconnected telephone line
Disconnected modem board
Check and set the correct user name (SP5816-156) and password
(SP5816-157).
-004 B
Incorrect modem setting
Dial up fails due to the incorrect modem setting.
Same as -001
Check and set the correct AT command (SP5816-160).
-005 -
Communication line error
The supplied voltage is not sufficient due to a defective communication line
or defective connection.
Same as -001