764 B
Paper position sensor slide motor error
The paper position sensor moves but is not detected at the home position
within the specified time.
The 1st detection failure causes a jam error, and the 2nd failure causes this
SC code.
Motor harness disconnected, loose, defective
Defective motor
765 B
Folding unit bottom fence lift motor
The folding unit bottom fence movement is not finished within a certain time.
The 1st detection failure causes a jam error, and the 2nd failure causes this
SC code.
Motor harness loose, broken
Motor drive obstructed
Motor defective
766 B
Clamp roller retraction motor error
The clamp roller movement is not finished within a certain time.
The 1st detection failure causes a jam error, and the 2nd failure causes this
SC code.
Motor harness loose, broken
Motor drive obstructed
Motor defective