Service Call Conditions
D009/D011/D012/D013/D091/D092 3-36 SM Appendix
760 B
Finisher punch motor error
The punch HP sensor is not activated within the specified time after the
punch motor turned on.
The 1st detection failure causes a jam error, and the 2nd failure causes this
SC code.
Punch HP sensor disconnected, defective
Punch motor disconnected or defective
Punch motor overload due to obstruction
761 B
Finisher folder plate motor error
The folder plate moves but is not detected at the home position within the
specified time.
The 1st detection failure causes a jam error, and the 2nd failure causes this
SC code.
Folder plate HP sensor disconnected, defective
Folder plate motor disconnected, defective
Folder plate motor overloaded due to obstruction.
763 B
Punch movement motor error
The punch unit moves but is not detected at the home position within the
specified time.
The 1st detection failure causes a jam error, and the 2nd failure causes this
SC code.
Motor harness disconnected, loose, defective
Defective motor