Service Call Conditions
D009/D011/D012/D013/D091/D092 3-44 SM Appendix
824 D
Self-diagnostic error : NVRAM
NVRAM device does not exist, NVRAM device is damaged, or NVRAM
socket damaged.
NVRAM defective
Controller board defective
NVRAM backup battery exhausted
NVRAM socket damaged
826 D Self-diagnostic Error: RTC/optional NVRAM
[1501]
The one second counted by the RTC is different from the one second
counted by the CPU on the controller.
Defective the RTC device
[15FF]
The RTC device is not detected.
Defective RTC device
NVRAM without RTC installed
Discharged backup battery
827 D
Self-diagnostic error: Standard SDRAM DIMM
[XXXX]: Detailed error code
[0201]
Verification error
Error detected during a write/verify check for the standard RAM (SDRAM
DIMM).
Loose connection
Defective SDRAM DIMM
Defective controller