Service Call Conditions
D009/D011/D012/D013/D091/D092 3-46 SM Appendix
833 C Self-diagnostic error 8: Engine I/F ASIC
[0F30]
[0F31]
ASIC (Mandolin) for system control could not be detected. After the PCI
configuration, the device ID for the ASIC could not be checked.
Replace the IPU.
[0F41]
ASIC (Mandolin) for system control could not be detected. After the PCI
configuration, the device ID for the ASIC could not be checked.
Replace the IPU.
[50B1]
Could not initialize or read the bus connection.
Check for loose connections at the mother board.
Replace the IPU.
[50B2]
Value of the SSCG register is incorrect.
Check for loose connections at the mother board.
Replace the IPU.
835 C Self-diagnostic error: Centronic device
[1102]
Loopback connector is connected but check results in an error.
IEEE1284 connector error
Centronic loopback connector defective
Replace the controller board.
[110C]
Loopback connector is connected but check results in an error.
ASIC device error
IEEE1284 connector error
Centronic loopback connector defective
Replace the controller board.