Service Call Conditions
SM Appendix 3-47 D009/D011/D012/D013/D091/D092
Appendix:
Service Call
Conditions
[1120]
Centronic loopback connector is not connected for detailed self-diagnostic
test.
Centronic loopback connector not connected correctly
Centronic loopback connector defective
ASIC device defective
Replace the controller board.
838 B Self-diagnostic Error: Clock Generator
[2701]
A verify error occurred when setting data was read from the clock generator
via the I2C bus.
Defective clock generator
Defective I2C bus
Defective I2C port on the CPU
Replace the controller board.
839 C USB NAND Flash ROM error
[9101]
The ID of the USB NAND Flash ROM cannot be read.
Defective controller board
[9110]
The USB NAND Flash ROM controller is disconnected.
Defective controller baord
851 B
IEEE 1394 I/F error
Driver setting incorrect and cannot be used by the 1394 I/F.
Not supported by this machine
NIB (PHY), LINK module defective; change the Interface Board
Controller board defective