Service Call Conditions
D009/D011/D012/D013/D091/D092 3-60 SM Appendix
In order to get more details about SC990 and SC991:
1) Execute SP7403 or print an SMC Report (SP5990) to read the history of the 10 most
recent logged errors.
2) If you press the zero key on the operation panel with the SP selection menu displayed,
you will see detailed information about the recently logged SC990 or SC991, including the
software file name, line number, and so on.
1) is the recommended method, because another SC could write over the
information for the previous SC.
992 D
Undefined error
Defective software program
An error undetectable by any other SC code occurred
994 C
Application Item Error
The number of executed application items on the operation panel reach
the maximum limit for the operation panel structure.
Too much executed application items
995 D
Controller Board Mismatch
The information on the controller board does not match that of the
machine