System SP Table-1
D009/D011/D012/D013/D091/D092 4-12 SM Appendix
1902 Cleaning Web Setting
001
Web Consumption
[0 to 120 / 0 / 1 %]
Displays the consumed amount of the web roll.
002
Web Motor Interval
C1b/C1.5b: [3 to 130 / 8.4 / 0.1 sec]
C1c/C1.5c: [3 to 130 / 6.7 / 0.1 sec]
Adjusts the interval for web motor rotation.
003
Web Motor Time
[0.3 to 10 / 4.2 / 0.1 sec]
Adjusts the rotation time of the web motor.
004
Web Near End Setting
C1b/C1.5b: EU [0 to 100 / 90 / 1 %]
C1b/C1.5b: ASIA/NA [0 to 100 / 92 / 1 %]
C1c/C1.5c: EU [0 to 100 / 90 / 1 %]
C1c/C1.5c: ASIA/NA [0 to 100 / 92 / 1 %]
Adjusts the threshold for web near end.
005
Web Motor Interval: Thick 1
[3 to 130 / 11.2 / 0.1 sec]
Adjusts the interval for web motor rotation (thick 1).
006
Web Motor Interval: Thick 2
[3 to 130 / 16.8 / 0.1 sec]
Adjusts the interval for web motor rotation (thick 2).
007
Paper Interval Time
[0 to 10 / 5 / 1 sec]
Adjusts the threshold for paper feeding. When the time between trailing
edge detection and leading edge detection is within the value of this setting,
the machine determines that the paper is still being fed.
008
Web Motor Setting: Web End
[0 to 60 / 27 / 1 sec]
Adjusts the motor rotation time after the web end.