System SP Table-2
SM Appendix 4-21 D009/D011/D012/D013/D091/D092
Appendix:
Service
Program
Mode Tables
013 Duplex Left: Thick
[0 to 1.5 / 0.1 / 0.1mm]
014 Duplex Right: Thick
2105*
LD Power Adjustment
Adjusts the LD power for each mode.
Each LD power setting is decided by the process control.
001 LD1: Copy
[–50 to 79 / -24 (D009/D011),
5 (D012/D013/D091/D092) /1 ]
002 LD2: Copy
003 LD1: Printer/Fax
[–50 to 79 / -44 (D009/D011),
-25 (D012/D013/D091/D092)/1 ]
004 LD2: Printer/Fax
2106*
POL REV TIME (Polygon motor rotation time)
001
PRE TIME
[0 to 60 / 10 /1 sec]
Adjusts the time of polygon motor rotation before a job.
If this is set to "0", this SP is not activated.
002
POST TIME
[0 to 60 / 0 /1 sec]
Adjusts the time of the polygon motor rotation after a job.
If this is set to "0", the polygon motor never switches off in standby mode.
However, if the machine enters the energy saver mode, the polygon motor
will ignore the zero setting and switch itself off.
⇒
⇒
Rev. 03/09/2012