System SP Table-2
SM Appendix 4-23 D009/D011/D012/D013/D091/D092
Appendix:
Service
Program
Mode Tables
2207
Forced Toner Supply
Forces the toner bottle to supply toner at 1-second intervals for up to 30
seconds. To start, press
.
2208*
Toner Supply Mode
[0: Sensor, 1: pixel ]
Selects the toner mode.
If you select "1", SP2-209-002 should be set to its default value. Use image
pixel count modes only as a temporary measure if the ID or TD sensor is
defective.
2209* Toner Supply Rate
001
Toner Rate
[10 to 800 / 60 mg/s / 5 mg ]
Sets the amount of toner supplied every second by the toner supply motor.
The length of time the motor remains on is determined by the data read by
the TD sensor and ID sensor.
Increasing this value reduces the toner supply clutch on time. Use a lower
value if the user tends to make lots of copies that have a high proportion of
black.
002
Correction Data
[25 to 300 / 300 / 25 ]
Displays the toner supply correction coefficient (K). It can also be used to
adjust K, but the value is changed again when VT is measured for the next
copy.
The toner supply rate depends on the amount of toner in the toner bottle.
This change is corrected using this coefficient. This SP can be used to
check the toner supply condition. The lower the value of K, the lower the
toner density