System SP Table-2
SM Appendix 4-31 D009/D011/D012/D013/D091/D092
Appendix:
Service
Program
Mode Tables
2810
Grayscale Setting
Initializes the LD power setting. This SP should be done after replacing the
drum.
2812* Drum Reverse Rotation (SSP)
001
Reverse time
[0 to 9 / 4 / 1 ]
Sets the reverse time of the drum motor after the end of a job.
002
Interval time
[0 to 19 / 9 /1 ]
Sets the waiting time of the drum motor reverse after the end of a job.
2912* Transfer Reverse Rotation
002
Interval
[0 to 10 / 3 / 1 ]
Sets the reverse time of the transfer/development motor after the end of a
job.
2914*
Paper Setting
001
C-alpha
[0 to 400 / 150 / 10vol ]
Adjusts the charge roller voltage used when paper with a small width is fed
from the by-pass tray. The paper width below which the correction starts
depends on the value of SP2-309-1.
Use this SP when an image problem (such as white spots at the center of
black dots or breaks in thin black lines) occurs when paper with a small
width is fed from the by-pass feed tray.