System SP Table-2
SM Appendix 4-35 D009/D011/D012/D013/D091/D092
Appendix:
Service
Program
Mode Tables
2976*
Bottle Motor Time
Displays the total ON time of the toner supply motor, calculated from when
the toner bottle was replaced. Use this to check that the toner end count
(SP2975) is working properly.
When SP2975 is set to any value other than "0", this value is displayed
when it matches the setting of SP2975. When SP2975 is set to "0", SP2976
is disabled. SP2976 is automatically set to zero by toner end recovery.)
Time
[0 to 7,000,000 / 0 / 1 msec]
2977*
Toner End Status
Indicates the toner near end or end condition.
001 Near End
[0 to 10 / 0 / 1 ]
0: Not detected
1: Detected by SP2975-001
2: Vt (10) - Vref > 0.2 and Vsp > 0.6
3: Vt (10) - Vref > 0.45
4: 0.45 > Vt (10) - Vref > 0.2 and toner end counter > 300
5 to 10: Not used
002 End
[0 to 10 / 0 / 1 ]
0: Not detected
1: Vsp > 2.0
2: Toner end counter > 90 when SP2213-001 is set to "0".
3: Toner end counter < 90 and Vt (10) > (Vref + 0.3) when
SP2213-001 is set to "0".
4: When SP2213-001 is set to "2"
5: Vsp > 0.9 when SP2213-001 is set to "2"
6: Special order
7 to 10: Not used