System SP Table-5
SM Appendix 4-89 D009/D011/D012/D013/D091/D092
Appendix:
Service
Program
Mode Tables
004
Rule Set (End)
Specifies the end setting for the summer time mode.
There are 8 digits in this SP.
1st and 2nd digits: The month. [1 to 12]
3rd digit: The week of the month. [0 to 5]
4th digit: The day of the week. [0 to 7 = Sunday to Saturday]
5th and 6th digits: The hour. [00 to 23]
The 7th and 8 digits must be set to "00".
The digits are counted from the left.
Make sure that SP5-307-1 is set to "1".
5401*
Access Control (DFU)
This SP stores the settings that limit uses access to SDK application data.
103
Default Document ACL
Whenever a new login user is added to the address book in external
certification mode (for Windows, LDAP, RDH), the default document ACL is
updated according to this SP setting.
[0 to 3 / 0 / 1]
0: View
1: Edit
2: Edit/Delete
3: Full control
Note: This SP setting is ignored on a machine that is not using document
server.
162 Extend Certification Detail
Selects the log out type for the extend
authentication device.
Bit 0: Log-out without an IC card
0: Not allowed (default)
1: Allowed
200 SDK1 Unique ID "SDK" is the "Software Development