Loading...
System SP Table-5
SM Appendix 4-93 D009/D011/D012/D013/D091/D092
Appendix:
Service
Program
Mode Tables
003
Monitor interval
[1 to 10 / 3 / 1 sec]
Sets the interval of watching out for user information and passwords.
5417 Access Attack
001
Access Permissible number
[0 to 500 / 100 / 1]
Sets a limit on access attempts to prevent password cracking.
002
Access Detect Time
[10 to 30 / 10 / 1 sec]
Sets a detection time to count password cracking.
003
Productivity Fall Weight
[0 to 9 / 3 / 1 sec]
Sets the wait time to slow down the speed of certification when an excessive
number of access attempts have been detected.
004
Attack Max Num
[50 to 200 / 200 / 1]
Sets a limit on the number of requests received for certification in order to
slow down the certification speed when an excessive number of access
attempts have been detected.
5420
User Authentication
These settings should be done with the System Administrator.
These functions are enabled only after the user access feature has
been enabled.
001 Copy
[0 or 1/ 0 / 1] 0: ON. 1: OFF
Determines whether certification is required
before a user can use the copy application.
011 Document Server
[0 or 1/ 0 / 1] 0: ON. 1: OFF
Determines whether certification is required
before a user can use the document server.

Table of Contents