System SP Table-7
D009/D011/D012/D013/D091/D092 4-178 SM Appendix
7852
ADF Exposure Glass
Counts the number of occurrences (0 to 65,535) when dust was detected on
the scanning glass of the ADF.
001* Dust Check Counter
Counts the occurrences. Counting is done
only if SP4020-1 (ADF Scan Glass Dust
Check) is switched on.
002* Dust Check Clear Counter
Clears the count. Memory All Clear
(SP5801) resets this counter to zero.
7853* Replacement Counter
001
PCD
[0 to 255 / 0 / 1 ]
Displays the replacement counter of the PCD (Drum and Development unit).
002
Transfer
[0 to 1 / 0 / 1 ]
Displays the replacement counter of the transfer unit.
003
Fuser
[0 to 1 / 0 / 1 ]
Displays the replacement counter of the fusing unit.
004
Web
[0 to 1 / 0 / 1 ]
Displays the replacement counter of the cleaning web.
7856* 1
Zero Cross
[0 to 255 / 60 / 1 ]
Stores and displays the detected zero cross frequency of the main ac power
supply from the wall socket.