Bit Switches
SM 89 D346
Fax Option
Type 5000
D346
1
Optional G3 unit (G3-2)
0: Off
1: On
Change this bit to "1" when installing the first
optional G3 unit (G3-2).
2
Not used
Do not change the factory settings.
3
Optional G3 unit (G3-3)
0: Off
1: On
Change this bit to "1" when installing the second
optional G3 unit (G3-3).
4-7
Not used
Do not change the factory settings.
Communication Switch 17 [SP No. 1-104-024]
No FUNCTION COMMENTS
0
SEP reception
0: Disabled
1: Enabled
0: Polling transmission to another maker’s
machine using the SEP (Selective Polling) signal
is disabled.
1
SUB reception
0: Disabled
1: Enabled
0: Confidential reception to another maker’s
machine using the SUB (Sub-address) signal is
disabled.
2
PWD reception
0: Disabled
1: Enabled
0: Disables features that require PWD (Password)
signal reception.
3-6
Not used
Do not change the factory settings.
7
Action when there is no box
with an F-code that matches
the received SUB code
0: Disconnect the line
1: Receive the message
(using normal reception mode)
Change this setting when the customer requires.
Communication Switch 18 [SP No. 1-104-025]