Bit Switches
D346 90 SM
No FUNCTION COMMENTS
0-4
Not used
Do not change the factory settings.
5
IP-Fax dial-in routing selection
0: Off
1: On
1: Transfers receiving data to each IP-Fax dial-in
number.
IP-Fax dial-in number is 4 digit-number.
6-7
Not used
Do not change the factory settings.
Communication Switch 19 - Not used (do not change the settings)
Communication Switch 1A - Not used (do not change the settings)
Communication Switch 1B [SP No. 1-104-028]
No FUNCTION COMMENTS
0-7
Extension access code (0 to 7)
to turn V.8 protocol On/Off
0: On
1: Off
If the PABX does not support V.8/V.34 protocol
procedure, set this bit to “1” to disable V.8.
Example: If “0” is the PSTN access code, set bit 0
to 1. When the machine detects “0” as the first
dialed number, it automatically disables V.8
protocol. (Alternatively, if “3” is the PSTN access
code, set bit 3 to 1.)
Communication Switch 1C [SP No. 1-104-029]
No FUNCTION COMMENTS
0-1
Extension access code (8 and
9) to turn V.8 protocol On/Off
0: On
1: Off
Refer to communication switch 1B.
Example: If “8” is the PSTN access code, set bit 0
to 1. When the machine detects “8” as the first
dialed number, it automatically disables V.8
protocol. (If “9” is the PSTN access code, use bit
1.)
2-7
Not used
Do not change the settings.