System Service Mode
D023/D025 8-258 SM Appendix
Connection Timing Adjustment: Incoming
162
When the Call Center calls out to a Cumin-M modem, it sends a repeating ID
tone (*#1#). This SP sets the line remains open to send these ID tones after
the number of the Cumin-M modem is dialed up and connected.
[0 to 24 / 1 / 1 /step]
The actual amount of time is this setting x 2 sec. For example, if you set "2"
the line will remain open for 4 sec.
Access Point
163
This is the number of the dial-up access point for Cumin-M. If no setting is
done for this SP code, then a preset value (determined by the country
selected) is used.
Default: 0
Allowed: Up to 16 alphanumeric characters
164 Line Connecting
This SP sets the connection conditions for the customer. This setting
dedicates the line to Cumin-M only, or sets the line for sharing between
Cumin-M and a fax unit.
[0 to 1 / 0 / 1 /step]
0: Sharing Fax
1: No Sharing Fax
If this setting is changed, the copier must be cycled off and on.
SP5816 187 determines whether the off-hook button can be used to
interrupt a Cumin-M transmission in progress to open the line for fax
transaction.
173 Modem Serial Number
This SP displays the serial number registered for
the Cumin-M.