SC4xx: Image Processing
435
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
Transfer unit not installed firmly
This is a logging SC (No action required).
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC497-00 C Image creation temperature sensor error
The thermistor output of the temperature sensor is not within the prescribed range (more than
0.5 V to less than 3.0 V).
Damaged or loose connector
Defective Image creation temperature sensor
Cycle the main power off/on to check if this SC occurs again.
If this SC reoccurs, do the following:
1. Reconnect all the related connectors, and cycle the main power off/on to check if the SC
reoccurs.
2.
Replace the image creation temperature sensor, and cycle the main power off/on to check
if the SC reoccurs.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC498-00 C Temperature/humidity sensor error
The thermistor output of the temperature sensor is not within the prescribed range (more
than 3.0V to less than 0.5V.
The thermistor output of the humidity sensor is not within the prescribed range (2.4V or
more).
Damaged or loose connector
Defective temperature/humidity sensor
Cycle the main power off/on to check if this SC occurs again.
If this SC reoccurs, do the following:
1. Reconnect all the related connectors, and cycle the main power off/on to check if the SC
reoccurs.
2.
Replace the temperature/humidity sensor, and cycle the main power off/on to check if the
SC reoccurs.