SC8xx: Overall System
478
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC858-00 A Data encryption conversion error (Key Setting Error)
A serious error occurred during an attempt to update the encryption key.
USB Flash, other data, corrupted
Communication error caused by electrostatic noise
Controller board defective
Replace the controller board.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC858-01 A Data encryption conversion error (HDD Key Setting Error)
A serious error occurred during an attempt to update the encryption key.
USB Flash, other data, corrupted
Communication error caused by electrostatic noise
Controller board defective
Cycle the main power off and on
If the error persists, replace the controller board.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC858-02 A Data encryption conversion error (NVRAM Read/Write Error)
A serious error occurred after
data conversion during an attempt to update the encryption key.
NVRAM defective
Replace the NVRAM.
Replace the controller board.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC858-30 A Data encryption conversion error (NVRAM Before Replace Error)
A serious error occurred after data conversion during an attempt to update the encryption key.
Software error such as conversion parameters being invalid.
Cycle the main power off and on.
If the error persists, replace the controller board.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC858-31 A Data encryption conversion error (Other Error)
A serious error occurred after data conversion during an attempt to update the encryption key.
Controller board defective
Replace the controller board.

Table of Contents