Process Control Error Conditions
501
No. Result Description Possible Causes/Action
Minimum Gamma < 0.15 too low.
Hardware defective.
1. Same as 53
2. Replace the toner supply
pump unit.
57 Vk error: Maximum Vk is out of range.
150 < Vk
ID sensor pattern density is
too low.
Hardware defective.
Same as 53
58 Vk error: Minimum Vk is out of range.
Vk < 150
ID sensor pattern density is
too high.
Background dirty
Hardware defective
Same as 53
59 Sampling data error
during gamma
correction
Not enough data can be sampled during
the gamma correction.
ID sensor pattern density is
too high or low.
Hardware defective
Same as 53
99 Unexpected error Process control fails.
Power Failure
Check the power source.
Vsg Adjustment Result
SP3-323-001 to -010 (Vsg Adjustment Result)
No. Result Description Possible Causes/Action
1 O.K Vsg adjustment is correctly done. -
2 ID sensor
adjustment error
Vsg cannot be adjusted within 4.0 ±0.5V.
Dirty ID sensor (toner, dust, or
foreign material)
Dirty transfer belt
Scratched image transfer belt
Defective ID sensor
Poor connection
Defective BICU
1. Clean the ID sensor.
2. Check the belt cleaning. Clean or
replace the transfer belt.
3. Replace the image transfer belt.
4. Replace the ID sensor.