Other Troubleshooting
524
6. Release the hook [A] from the hole where the bracket was removed.
When Fluorescent or LED Lamps Flicker
Problem:
Under the usage environment of this machine, at the placement location, fluorescent and/or LED lamps flicker.
Causes:
This is a result of the voltage drop that occurs when power is applied to the fusing lamp. It depends on the
electrical power environment at the customer's location.
Solutions:
The procedure varies by the flicker occurrence timing. So check the occurrence timing, and do the procedure
that matches the timing.
Occurrence Timing:
Timing Solutions Side Effect
Recovery from energy
saving
Set SP1-135-001 (Inrush
Control) to "1 (ON)."
Recovery time from energy saving becomes slower
approx. 0.4 sec.
After the recovery
from energy saving
Set SP1-135-001 (Inrush
Control) to "1 (ON)."
Set SP1-190-001 (Flicker
Control) to "1 (ON)."
• Recovery time from energy saving becomes
slower approx. 0.4 sec..
• If the adhesion amount of an image is large, an
offset may occur.