3.SP Mode Tables
37
1: Fusing Quality
Mode 1
2: Fusing Quality
Mode 2
1-132-
012
Voltage Detection Voltage Detection ENG* [ 0 to 650 / 0 / 0.1V ]
1-132-
014
Voltage Detection Max ENG* [ 0 to 350 / 0 / 0.1V ]
1-132-
015
Voltage Detection Min ENG* [ 0 to 350 / 0 / 0.1V ]
1-132-
016
Voltage Detection Latest ENG* [ 0 to 350 / 0 / 0.1V ]
1-132-
017
Voltage Detection SC Detection ENG* [ 0 to 350 / 0 / 0.1V ]
1-132-
018
Voltage Detection Max(standby) ENG* [ 0 to 350 / 0 / 0.1V ]
1-132-
019
Voltage Detection Min(standby) ENG* [ 0 to 350 / 0 / 0.1V ]
1-135-
001
Inrush Control Inrush Control ENG* [ 0 or 1 / 0 / 1 ]
1-136-
001
Engy Svg Paper Feed
Judg.
Control ON/OFF ENG* [ 0 or 1 / 1 / 1 ]
0: OFF
1: ON
1-141-
001
Fusing SC Issue Time
Info
SC Number ENG* [ 0 to 99999 / 0 / 1 ]
1-141-
101
Fusing SC Issue Time
Info
Heating Roller Temperature
1:Center
ENG* [ -50 to 260 / 0 / 1deg ]
1-141-
104
Fusing SC Issue Time
Info
Heating Roller Temperature 1:End ENG* [ -50 to 260 / 0 / 1deg ]
1-141-
107
Fusing SC Issue Time
Info
Press Roller Temperature 1 ENG* [ -50 to 260 / 0 / 1deg ]
1-141-
108
Fusing SC Issue Time
Info
Press Roller: End R Temperature 1 ENG* [ -50 to 260 / 0 / 1deg ]
1-141-
109
Fusing SC Issue Time
Info
Press Roller: End F Temperature 1 ENG* [ -50 to 260 / 0 / 1deg ]
1-141-
151
Fusing SC Issue Time
Info
Heating Roller Temperature
2:Center
ENG* [ -50 to 260 / 0 / 1deg ]
1-141- Fusing SC Issue Time Heating Roller Temperature 2:End ENG* [ -50 to 260 / 0 / 1deg ]