3.SP Mode Tables
38
154 Info
1-141-
157
Fusing SC Issue Time
Info
Press Roller Temperature 2 ENG* [ -50 to 260 / 0 / 1deg ]
1-141-
158
Fusing SC Issue Time
Info
Press Roller.End R Temperature 2 ENG* [ -50 to 260 / 0 / 1deg ]
1-141-
159
Fusing SC Issue Time
Info
Press Roller.End F Temperature 2 ENG* [ -50 to 260 / 0 / 1deg ]
1-141-
201
Fusing SC Issue Time
Info
Heating Roller Temperature
3:Center
ENG* [ -50 to 260 / 0 / 1deg ]
1-141-
204
Fusing SC Issue Time
Info
Heating Roller Temperature 3:End ENG* [ -50 to 260 / 0 / 1deg ]
1-141-
207
Fusing SC Issue Time
Info
Press Roller Temperature 3 ENG* [ -50 to 260 / 0 / 1deg ]
1-141-
208
Fusing SC Issue Time
Info
Press Roller.End R Temperature 3 ENG* [ -50 to 260 / 0 / 1deg ]
1-141-
209
Fusing SC Issue Time
Info
Press Roller.End F Temperature 3 ENG* [ -50 to 260 / 0 / 1deg ]
1-142-
001
Fusing Jam Detection SC Display ENG* [ 0 or 1 / 0 / 1 ]
0: OFF
1: ON
1-152-
001
Fusing Nip Band
Check
Execute ENG [ 0 or 1 / 0 / 1 ]
1-158-
001
Abnormal Noise
Confirmation
Unit: Execute ENG [ 0 or 1 / 0 / 1 ]
1-158-
002
Abnormal Noise
Confirmation
No Unit: Execute ENG [ 0 or 1 / 0 / 1 ]
1-158-
003
Abnormal Noise
Confirmation
Operation Time ENG* [ 0 to 200 / 20 / 1sec ]
1-158-
004
Abnormal Noise
Confirmation
Operation Line Speed ENG* [ 0 to 3 / 0 / 1 ]
0: 89mm/s (C307,
C407)
1: 178mm/s (C307,
C407)
2: 212mm/s (C407)
3: 252mm/s (C407)
1-158-
005
Abnormal Noise
Confirmation
Heat Center Target Temp ENG* [ 100 to 180 / * /
1deg ]
*MP C307:154