3.SP Mode Tables
64
2-
194-
012
MUSIC Execution Result Error Result: Y ENG* [ 0 to 9 / 0 / 1 ]
2-
194-
013
MUSIC Execution Result Error Result: Bk ENG* [ 0 to 9 / 0 / 1 ]
2-
221-
001
LD Power: Fixed: Set Standard Speed: Bk ENG* [ 0 to 200 / 100 / 1% ]
2-
221-
002
LD Power: Fixed: Set Standard Speed: C ENG* [ 0 to 200 / 100 / 1% ]
2-
221-
003
LD Power: Fixed: Set Standard Speed: M ENG* [ 0 to 200 / 100 / 1% ]
2-
221-
004
LD Power: Fixed: Set Standard Speed: Y ENG* [ 0 to 200 / 100 / 1% ]
2-
221-
011
LD Power: Fixed: Set Low Speed: M ENG* [ 0 to 200 / 100 / 1% ]
2-
221-
012
LD Power: Fixed: Set Low Speed: Y ENG* [ 0 to 200 / 100 / 1% ]
2-
229-
001
Develop DC Bias: Fixed Standard Speed: Bk ENG* [ 0 to 800 / 450 / 1-V ]
2-
229-
002
Develop DC Bias: Fixed Standard Speed: C ENG* [ 0 to 800 / 450 / 1-V ]
2-
229-
003
Develop DC Bias: Fixed Standard Speed: M ENG* [ 0 to 800 / 450 / 1-V ]
2-
229-
004
Develop DC Bias: Fixed Standard Speed: Y ENG* [ 0 to 800 / 450 / 1-V ]
2-
241-
003
PCDU Temperature: Display Time Interval: Fan
Extension Control
ENG* [ 1 to 300 / 10 / 1sec ]