3.SP Mode Tables
65
2-
241-
004
PCDU Temperature: Display PCDU Temperature ENG [ 0 to 70 / 0 / 0.1deg ]
2-
242-
001
TS Operation Env. Log Distance: PCU: Bk:
TS<=A-3
ENG [ 0 to 99999999 / 0 /
1mm ]
2-
242-
002
TS Operation Env. Log Distance: PCU: Bk: A-
3<TS<=A
ENG [ 0 to 99999999 / 0 /
1mm ]
2-
242-
003
TS Operation Env. Log Distance: PCU: Bk:
A<TS<=A+3
ENG [ 0 to 99999999 / 0 /
1mm ]
2-
242-
004
TS Operation Env. Log Distance: PCU: Bk:
A+3<TS
ENG [ 0 to 99999999 / 0 /
1mm ]
2-
242-
100
TS Operation Env. Log Log Clear ENG [ 0 or 1 / 0 / 1 ]
2-
302-
001
Environmental Correction:Trans Current Environmental
Display
ENG [ 0 or 0 / 0 / 0 ]
2-
302-
002
Environmental Correction:Trans Forced Setting ENG* [ 0 or 6 / 0 / 1 ]
2-
302-
003
Environmental Correction:Trans Absolute
Humidity:Threshold 1
ENG* [ 0 to 100 / 4.5 /
0.01g/m3 ]
2-
302-
004
Environmental Correction:Trans Absolute
Humidity:Threshold 2
ENG* [ 0 to 100 / 9 /
0.01g/m3 ]
2-
302-
005
Environmental Correction:Trans Absolute
Humidity:Threshold 3
ENG* [ 0 to 100 / 17.5 /
0.01g/m3 ]
2-
302-
006
Environmental Correction:Trans Absolute
Humidity:Threshold 4
ENG* [ 0 to 100 / 24 /
0.01g/m3 ]
2-
302-
007
Environmental Correction:Trans Temperature:Threshold ENG* [ -5 to 30 / 10 / 1deg ]