3.SP Mode Tables
146
003
3-132-
004
Delta Vt Sum: Display Y ENG* [ 0 to 99 / 0 / 0.01V ]
3-200-
001
Toner Density: Display Bk ENG* [ 0 to 25.5 / 0 / 0.1wt% ]
3-200-
002
Toner Density: Display C ENG* [ 0 to 25.5 / 0 / 0.1wt% ]
3-200-
003
Toner Density: Display M ENG* [ 0 to 25.5 / 0 / 0.1wt% ]
3-200-
004
Toner Density: Display Y ENG* [ 0 to 25.5 / 0 / 0.1wt% ]
3-201-
001
Toner Density Limits: Set Upper TC ENG* [ 1 to 15 / 8.5 / 0.1wt% ]
3-201-
002
Toner Density Limits: Set Lower TC ENG* [ 1 to 15 / 1 / 0.1wt% ]
3-206-
001
TD Sensor Bulk Corr.: Set Abs. Humidity Cnver.
Coef.: Bk
ENG* [ 0 to 6.5535 / 0.4945 /
0.0001g/cm3/g/m3 ]
3-206-
002
TD Sensor Bulk Corr.: Set Abs. Humidity Cnver.
Coef.: C
ENG* [ 0 to 6.5535 / 0.4945 /
0.0001g/cm3/g/m3 ]
3-206-
003
TD Sensor Bulk Corr.: Set Abs. Humidity Cnver.
Coef.: M
ENG* [ 0 to 6.5535 / 0.4945 /
0.0001g/cm3/g/m3 ]
3-206-
004
TD Sensor Bulk Corr.: Set Abs. Humidity Cnver.
Coef.: Y
ENG* [ 0 to 6.5535 / 0.4945 /
0.0001g/cm3/g/m3 ]
3-206-
011
TD Sensor Bulk Corr.: Set Color Conversion Coef.:
Bk
ENG* [ 0 to 200 / 100 / 1% ]
3-206-
012
TD Sensor Bulk Corr.: Set Color Conversion Coef.: C ENG* [ 0 to 200 / 100 / 1% ]
3-206-
013
TD Sensor Bulk Corr.: Set Color Conversion Coef.:
M
ENG* [ 0 to 200 / 100 / 1% ]
3-206-
014
TD Sensor Bulk Corr.: Set Color Conversion Coef.: Y ENG* [ 0 to 200 / 100 / 1% ]
3-206-
021
TD Sensor Bulk Corr.: Set Weight Coefficient ENG* [ 0 to 200 / 100 / 1% ]
3-206-
031
TD Sensor Bulk Corr.: Set Offset: Bk ENG* [ -2 to 2 / 0 / 0.0001g/cm3 ]
3-206-
032
TD Sensor Bulk Corr.: Set Offset: C ENG* [ -2 to 2 / 0 / 0.0001g/cm3 ]
3-206- TD Sensor Bulk Corr.: Set Offset: M ENG* [ -2 to 2 / 0 / 0.0001g/cm3 ]

Table of Contents