3.SP Mode Tables
147
033
3-206-
034
TD Sensor Bulk Corr.: Set Offset: Y ENG* [ -2 to 2 / 0 / 0.0001g/cm3 ]
3-206-
041
TD Sensor Bulk Corr.: Set Conversion Coeff. Beta:
Bk
ENG* [ -999 to 0 / -1 /
0.1count/g/cm3 ]
3-206-
042
TD Sensor Bulk Corr.: Set Conversion Coeff. Beta: C ENG* [ -999 to 0 / -1 /
0.1count/g/cm3 ]
3-206-
043
TD Sensor Bulk Corr.: Set Conversion Coeff. Beta:
M
ENG* [ -999 to 0 / -1 /
0.1count/g/cm3 ]
3-206-
044
TD Sensor Bulk Corr.: Set Conversion Coeff. Beta: Y ENG* [ -999 to 0 / -1 /
0.1count/g/cm3 ]
3-210-
001
TD Sensor: Vt: Display Current: Bk ENG* [ 0 to 5.5 / 0 / 0.01V ]
3-210-
002
TD Sensor: Vt: Display Current: C ENG* [ 0 to 5.5 / 0 / 0.01V ]
3-210-
003
TD Sensor: Vt: Display Current: M ENG* [ 0 to 5.5 / 0 / 0.01V ]
3-210-
004
TD Sensor: Vt: Display Current: Y ENG* [ 0 to 5.5 / 0 / 0.01V ]
3-212-
101
Vt Shift: Set TC Cor.(ON/OFF) ENG* [ 0 or 1 / 1 / 1 ]
0: OFF
1: ON
3-213-
001
Vt Shift: Set TC Cor.(ON/OFF) ENG* [ 0 or 1 / 1 / 1 ]
0: OFF
1: ON
3-213-
021
Vt Shift: Set Low Speed TC
Correction: Bk
ENG* [ -0.5 to 0.5 / 0 / 0.01V ]
3-213-
022
Vt Shift: Set Low Speed TC
Correction: C
ENG* [ -0.5 to 0.5 / 0 / 0.01V ]
3-213-
023
Vt Shift: Set Low Speed TC
Correction: M
ENG* [ -0.5 to 0.5 / 0 / 0.01V ]
3-213-
024
Vt Shift: Set Low Speed: TC
Correction: Y
ENG* [ -0.5 to 0.5 / 0 / 0.01V ]
3-213-
031
Vt Shift: Set Std Speed 2 TC
Correction: Bk
ENG* [ -0.5 to 0.5 / 0 / 0.01V ]
3-214-
001
Vt Save: Set Dot Coverage Thresh ENG* [ 0 to 100 / 20 / 1% ]
3-230- Vtref: Display/Set Current: Bk ENG* [ 0 to 5 / 1.5 / 0.01V ]