Remote Control Commands
R&S
®
RTB2000
384User Manual 1333.1611.02 ─ 04
BUS<b>:I2C:DATA:SOURce <Source>
Sets the input channel to which the data line is connected.
Suffix: 
<b>
.
1 | 2
Parameters:
<Source> CH1 | CH2 | CH3 | CH4 | D0..D15
CH3 and CH4 are only available with 4-channel R&S RTB2000
oscilloscopes.
*RST:  CH1
15.11.3.2 I²C - Trigger
To configure the protocol trigger, make sure to set first:
●
TRIGger:A:TYPE to BUS
●
TRIGger:A:SOURce to SBUS1 | SBUS2
TRIGger:A:I2C:MODE.................................................................................................... 384
TRIGger:A:I2C:ACCess..................................................................................................385
TRIGger:A:I2C:AMODe.................................................................................................. 385
TRIGger:A:I2C:ADDRess................................................................................................386
TRIGger:A:I2C:PATTern.................................................................................................386
TRIGger:A:I2C:PLENgth.................................................................................................386
TRIGger:A:I2C:POFFset.................................................................................................387
TRIGger:A:I2C:MODE <Mode>
Specifies the trigger mode for I²C.
 
Serial Bus Analysis