Remote Control Commands
R&S
®
RTB2000
443User Manual 1333.1611.02 ─ 04
Parameters:
<DutyCycle> Numeric value
Range:  1.000E+01  to  9.000E+01
*RST:  2.500E+01
Default unit: %
WGENerator:FUNCtion:PULSe:ETIMe <EdgeTime>
Sets the pulse edge time.
Parameters:
<EdgeTime>
WGENerator:FUNCtion:EXPonential:POLarity 
<Polarity>
Sets the polarity of the generator function exponential.
Parameters:
<Polarity> POSitive | NEGative
WGENerator:FUNCtion:RAMP:POLarity <Polarity>
Sets the polarity of the generator function ramp.
Parameters:
<Polarity> POSitive | NEGative
*RST:  NEG
WGENerator:ARBitrary:SOURce <Source>
Selects the input channel for an arbitrary function to be generated.
Parameters:
<Source> CH1 | CH2 | CH3 | CH4
*RST:  CH1
WGENerator:ARBitrary:UPDate
Loads the waveform from the selected signal source (WGENerator:ARBitrary:
SOURce).
Usage: 
Event
WGENerator:ARBitrary[:FILE]:NAME <FilePath>
Sets the file path and the file for an arbitrary waveform to be loaded.
Signal Generation (Option R&S
 RTB-B6)