Protocol Analysis
R&S
®
RTM20xx
206User Manual 1317.4726.02 ─ 01
The setting is only available if "Event" = "Frame" is selected.
Remote command: 
SEARch:PROTocol:LIN:FRAMe on page 432
Error Setup
Selects the error type to be searched for. You can select one or more error types as
search condition.
The error types are the same as in the LIN trigger setup, see "Error <type>"
on page 200.
The setting is only available if "Event" = "Error" or "ID & Error" is selected.
Remote command: 
SEARch:PROTocol:LIN:CHKSerror on page 433
SEARch:PROTocol:LIN:IPERror on page 433
SEARch:PROTocol:LIN:SYERror on page 433
Symbolic ID
If a label list with node names was loaded and applied in the bus configuration, you can
select simply the node name from the list instead of entering the numeric identifier.
The instrument trriggers on the identifier of the selected node.
Identifier Setup
Opens the menu to set the identifier pattern, if "Event" = "Identifier" or "ID & Data" or "ID
& Error" is selected.
The settings are the same as for the setup of the identifier trigger, see "Identifier"
on page 200.
Remote command: 
SEARch:PROTocol:LIN:ICONdition on page 433
SEARch:PROTocol:LIN:IDENtifier on page 433
Data Setup
Opens the menu to set the data pattern to be searched, if "Event" = "ID & Data" is
selected.
After setting the "No. of Bytes" and the "Comparison" condition, you can enter the value
bit-by-bit by setting the state high, low, or don't care for each single bit. Alternatively, you
can enter a hexadecimal value for each byte.
The settings are the same as for the setup of the data trigger, see "Data Setup"
on page 202.
Remote command: 
SEARch:PROTocol:LIN:DLENgth on page 434
SEARch:PROTocol:LIN:DCONdition on page 434
SEARch:PROTocol:LIN:DATA on page 434