Remote Control
R&S
®
RTM20xx
316User Manual 1317.4726.02 ─ 01
DISPlay:XY:Y2Source <Source>
Defines an optional second source to be displayed in y direction in an XY-diagram. The
command is only relevant for 4-channel R&S RTM instruments.
Parameters:
<Source> NONE | CH1 | CH2 | CH3 | CH4
*RST: NONE
DISPlay:XY:ZMODe <Mode>
Activates or deactivates the intensity control of the waveform via an additional signal
source and sets the intensity mode.
Parameters:
<Mode> ANALog | DIGital | OFF
ANALog
Modulated intensity; Intensity is modulated continuously accord-
ing to the selected Source Z.
DIGital
Intensity is determined by a threshold value defined with
DISPlay:XY:ZTHReshold. If the Z signal value is below the
selected threshold, the corresponding x/y point is not displayed. If
the Z signal value is above the threshold, the x/y point is displayed
with the defined intensity level.
OFF
Intensity control is deactivated.
*RST:
OFF
DISPlay:XY:ZTHReshold <Zthreshold>
Defines the threshold for intensity with a two-state modulation, if DISPlay:XY:ZMODe
is set to DIGital.
Parameters:
<Zthreshold> Threshold for visibility on the screen
Range: -10 to 10
Increment: depends on the scaling of the channel that is
assigned to Z
*RST: 0
Default unit: V
DISPlay:XY:ZSOurce <Source>
Defines the source to be used to determine the intensity of the xy-waveform.
Command Reference

Table of Contents

Related product manuals