Remote Control
R&S
®
RTM20xx
317User Manual 1317.4726.02 ─ 01
Parameters:
<Source> CH1 | CH2 | CH3 | CH4
CH3 and CH4 are only available with 4-channel R&S RTM oscil-
loscopes.
*RST: CH1
Intensities
DISPlay:INTensity:WAVeform.........................................................................................317
DISPlay:INTensity:BACKlight..........................................................................................317
DISPlay:INTensity:GRID.................................................................................................317
DISPlay:PERSistence:STATe..........................................................................................318
DISPlay:PERSistence:TIME............................................................................................318
DISPlay:PERSistence:INFinite.........................................................................................318
DISPlay:PERSistence:TIME:AUTO..................................................................................318
DISPlay:PERSistence:CLEar..........................................................................................319
DISPlay:INTensity:WAVeform <Intensity>
Defines the strength of the waveform line in the diagram.
Parameters:
<Intensity> Value in percent
Range: 0 to 100
Increment: 1
*RST: not available, *RST does not change the intensity
Default unit: %
DISPlay:INTensity:BACKlight <Intensity>
Defines the intensity of the background lighting of the display.
Parameters:
<Intensity> Value in percent
Range: 10 to 100
Increment: 1
*RST: not available, *RST does not change the intensity
Default unit: %
DISPlay:INTensity:GRID <Intensity>
Defines the intensity of the grid on the screen.
Parameters:
<Intensity> Value in percent
Range: 0 to 100
Increment: 1
*RST: not available, *RST does not change the intensity
Default unit: %