Remote Control
R&S
®
RTM20xx
410User Manual 1317.4726.02 ─ 01
TRIGger:A:CAN:DATA <Data>
Defines the data pattern. The number of bytes in the data pattern is defined with 
TRIGger:A:CAN:DLC.
The command is relevant if TRIGger:A:CAN:TYPE is set to IDDT.
Parameters:
<Data> String containing binary pattern with max. 64 bit. Characters 0, 1,
and X are allowed. Make sure to enter complete bytes.
TRIGger:
A:CAN:ACKerror <AcknowledgeError>
Triggers on acknowledgement errors. An acknowledgement error occurs when the trans-
mitter does not receive an acknowledgment - a dominant bit during the Ack Slot.
The command is relevant if TRIGger:A:CAN:TYPE is set to ERRCondition.
Parameters:
<AcknowledgeError> ON | OFF
*RST:  OFF
TRIGger:A:CAN:BITSterror <BitStuffingError>
Triggers on bit stuffing errors.
See also: "Stuff bit" on page 188.
The command is relevant if TRIGger:A:CAN:TYPE is set to ERRCondition.
Parameters:
<BitStuffingError> ON | OFF
*RST:  ON
TRIGger:A:CAN:CRCerror <CRCerror>
Triggers on errors in the Cyclic Redundancy Check.
The command is relevant if TRIGger:A:CAN:TYPE is set to ERRCondition.
Parameters:
<CRCerror> ON | OFF
*RST:  OFF
TRIGger:A:CAN:FORMerror <FormError>
Triggers on form errors. A form error occurs when a fixed-form bit field contains one or
more illegal bits.
The command is relevant if TRIGger:A:CAN:TYPE is set to ERRCondition.
Command Reference