EasyManua.ls Logo

Rohde & Schwarz RTM2032 - Page 442

Rohde & Schwarz RTM2032
499 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Control
R&S
®
RTM20xx
427User Manual 1317.4726.02 ─ 01
Suffix:
<b>
.
1..4
Selects the bus.
<n> *
Selects the frame (1...n).
Return values:
<FrameData> Comma-separated list of decimal values of the data bytes.
Usage: Query only
BUS<b>:
LIN:FRAMe<n>:STATus?
Suffix:
<b>
.
1..4
Selects the bus.
<n> *
Return values:
<FrameStatus> OK | UART | CHCKsum | PRERror | SYERror | WAKeup |
INSufficient | ERR | LENer
Usage: Query only
BUS<b>:LIN:FRAMe<n>:STARt?
Returns the start time of the specified frame.
Suffix:
<b>
.
1..4
Selects the bus.
<n> *
Selects the frame (1...n).
Return values:
<StartTime> Range: depends on sample rate, record length, and time
base
Increment: depends on the time base
Default unit: s
Usage: Query only
BUS<b>:LIN:FRAMe<n>:STOP?
Returns the end time of the specified frame.
Suffix:
<b>
.
1..4
Selects the bus.
Command Reference

Table of Contents