Remote Control
R&S
®
RTM20xx
439User Manual 1317.4726.02 ─ 01
Parameters:
<Polarity> POSitive | NEGative
POSitive = high active
NEGative = low active
Parallel Buses - Decode Results
The commands to query results of decoded parallel clocked and unclocked buses are
similar and described together in this chapter..
BUS<b>:PARallel:FCOunt?.............................................................................................439
BUS<b>:CPARallel:FCOunt?..........................................................................................439
BUS<b>:PARallel:FRAMe<n>:DATA?..............................................................................439
BUS<b>:CPARallel:FRAMe<n>:DATA?............................................................................439
BUS<b>:PARallel:FRAMe<n>:STATe?............................................................................440
BUS<b>:CPARallel:FRAMe<n>:STATe?..........................................................................440
BUS<b>:PARallel:FRAMe<n>:STARt?.............................................................................440
BUS<b>:CPARallel:FRAMe<n>:STARt?...........................................................................440
BUS<b>:PARallel:FRAMe<n>:STOP?..............................................................................440
BUS<b>:CPARallel:FRAMe<n>:STOP?...........................................................................440
BUS<b>:PARallel:FCOunt?
BUS<b>:CPARallel:FCOunt?
Returns the number of decoded frames.
Suffix:
<b>
.
1..4
Selects the bus.
Note: SPI/SSPI and UART protocols occupy two bus lines.
Return values:
<FrameCount> Total number of decoded frames.
Usage: Query only
BUS<b>:PARallel:FRAMe<n>:DATA?
BUS<b>:CPARallel:FRAMe<n>:DATA?
Returns the data words of the specified frame.
Suffix:
<b>
.
1..4
Selects the bus.
Note: SPI/SSPI and UART protocols occupy two bus lines.
<n> *
Selects the frame.
Return values:
<FrameData> List of decimal values of data words
Usage: Query only
Command Reference